Electric Power Distribution: How Global Lines/Hot Voltages Work

Electric power distribution is the process of delivering electricity from the generation sources to the end users. It is a complex and vital system that forms the backbone of modern society, powering industries, homes, and devices. It involves the use of high voltage power lines, transformers, substations, and distribution lines, each with their own characteristics and challenges.

High Voltage Power Lines

High voltage power lines are the main arteries of the electric power system, carrying electricity over long distances from the power plants to the distribution substations. They operate at very high voltages, ranging from 36 kV to 1000 kV, depending on the region and the type of transmission. High voltage power lines can be either alternating current (AC) or direct current (DC), each with their own advantages and disadvantages.

AC power lines are more common and can easily change the voltage level using transformers. They also have lower losses and can transmit more power than DC lines. However, AC power lines also have some drawbacks, such as the need for synchronization, the generation of reactive power, and the susceptibility to electromagnetic interference.

DC power lines are less common and require converters to change the voltage level and the current direction. They have higher costs and lower reliability than AC lines. However, DC power lines also have some benefits, such as the ability to transmit power over long distances without losses, the elimination of reactive power, and the independence from frequency and synchronization.

Transformers

Transformers are devices that change the voltage level of an electric current. They are essential for the electric power distribution system, as they allow the power to be transmitted at high voltages to reduce losses and then stepped down to lower voltages for distribution and consumption. Transformers can be either step-up or step-down, depending on whether they increase or decrease the voltage level.

Transformers consist of two or more coils of wire that are wrapped around a core of iron or other magnetic material. When an electric current flows through one coil, called the primary, it creates a magnetic field that induces a voltage in the other coil, called the secondary. The ratio of the number of turns of wire in the primary and secondary coils determines the voltage change. For example, if the primary coil has 100 turns and the secondary coil has 10 turns, the voltage will be reduced by a factor of 10.

Transformers can be either single-phase or three-phase, depending on whether they handle one or three alternating currents. Single-phase transformers are simpler and cheaper, but they have lower efficiency and capacity than three-phase transformers. Three-phase transformers are more complex and expensive, but they have higher efficiency and capacity than single-phase transformers. They are also more suitable for industrial applications that require high power and balanced loads.

Substations

Substations are facilities that connect the high voltage power lines to the medium and low voltage distribution lines. They perform several functions, such as:

  • Switching: Substations have circuit breakers and switches that can isolate or connect different parts of the electric power system, such as transmission lines, distribution lines, generators, and loads. This allows for maintenance, protection, and control of the system.
  • Transforming: Substations have transformers that step down the high voltage power to the medium and low voltage levels for distribution and consumption. They also have voltage regulators that maintain a constant voltage level for the distribution lines.
  • Metering: Substations have meters that measure the amount of power and energy that flows through the system. This allows for billing, monitoring, and planning of the system.
  • Protection: Substations have protective devices that detect and clear faults in the system, such as overcurrent, overvoltage, short circuit, and ground fault. These devices include fuses, relays, circuit breakers, and surge arresters. They prevent damage to the equipment and ensure the safety of the system.

Distribution Lines

Distribution lines are the final stage of the electric power distribution system, delivering electricity to the end users. They operate at medium and low voltages, typically between 0.23 kV and 33 kV, depending on the region and the type of load. Distribution lines can be either overhead or underground, each with their own pros and cons.

Overhead distribution lines are more common and cheaper to install and maintain. They also have better cooling and lower losses than underground lines. However, overhead distribution lines also have some disadvantages, such as the exposure to weather, animals, vegetation, and vandalism. They also have higher visual and environmental impact than underground lines.

Underground distribution lines are less common and more expensive to install and maintain. They also have worse cooling and higher losses than overhead lines. However, underground distribution lines also have some advantages, such as the protection from weather, animals, vegetation, and vandalism. They also have lower visual and environmental impact than overhead lines.

Voltage Levels and Frequencies

The voltage levels and frequencies used in the electric power distribution system vary from region to region, depending on the historical, technical, and economic factors. The following table summarizes the typical voltage levels and frequencies used in different parts of the world:

Region Transmission Voltage (kV) Distribution Voltage (kV) Utilization Voltage (V) Frequency (Hz)
North America 69-765 2.4-34.5 120/240 (single-phase), 208/480 (three-phase) 60
Europe 110-750 10-30 230/400 (single-phase or three-phase) 50
Asia 66-765 6.6-33 220/380 (single-phase or three-phase) 50 or 60
Africa 66-765 11-33 220/380 (single-phase or three-phase) 50
Australia 66-500 11-22 230/400 (single-phase or three-phase) 50
South America 69-765 13.8-34.5 127/220 (single-phase), 220/380 (three-phase) 50 or 60

 